Deye Suscipe plures gravidae parallelas SOL 25 / 30 / 40 / 50 K-SG01HP3-EU-BM2/3/4
| Model | SOL-25K-SG01HP3 -EU-BM2 | SOL-30K-SG01HP3 -EU-BM3 | SOL-40K-SG01HP3 -EU-BM4 | SOL-50K-SG01HP3 -EU-BM4 |
| Pugna Input Data | Li-lon | |||
| Type altilium | 160~800 | |||
| Pugna intentione Range (V) | 50+50 | |||
| Maximilianus. missionem Current (A) | 50+50 | |||
| Numerus altilium initus | 2 | |||
| Incurrens Strategy pro Li-Ion altilium | Adaptatio auto-BMS | |||
| PV String Input Data | ||||
| Maximilianus. DC Input Power (W) | 32500 | 39000 | 52000 | 65000 |
| Maximilianus. DC Input Voltage (V) | 1000 | |||
| Satus-usque intentione (V) | 180 | |||
| MPPT Range (V) | 150-850 | |||
| Full Load DC Voltage Range (V) | 450-850 | 360-850 | 360-850 | 450-850 |
| Ratum DC Input Voltage (V) | 600 | |||
| PV Input Current (A) | 36+36 | 36+36+36 | 36+36+36+36 | |
| Maximilianus. PV I (A); | 55+55 | 55+55+55 | 55+55+55+55 | |
| No.of MPP Trackers | 2 | 3 | 4 | |
| No.of Gloria per MPP Tracker | 2 | |||
| AC Output Data | ||||||||
| Rated AC Output et UPS Power (W) | 25000 | 30000 | 40000 | 50000 | ||||
| Maximilianus. AC Output Power (W) | 27500 | 33000 | 44000 | 55000 | ||||
| AC Output Rated Current (A) | 37.9/36.3 | 45.5/43.5 | 60.7/58 | 75.8/72.5 | ||||
| Maximilianus. AC Current (A) | 50 | 60 | 70 | 83.3 | ||||
| Maximilianus. Continuus AC Passthrough (A) | 150 | |||||||
| Apicem Power (offff eget) | 1.5 tempore virtutis aestimatae, 10 S | |||||||
| Generator initus / Smart onus /AC current duobus (A) | 37.9/150/ 37.9 | 45.5 / 150 / 45.5 | 60.8 / 150 / 60.8 | 75.8 / 150 / 75.8 | ||||
| Potestas Factor | 0,8 ducens ad 0.8 pigri | |||||||
| Output Frequency et intentione | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | |||||||
| Eget Type | Tres Phase | |||||||
| DC iniectio venae (mA) | <0.5%1n | |||||||
| Efficaciam | ||||||||
| Maximilianus. Efficaciam | 97.60% | |||||||
| Effectus Euro | 97.00% | |||||||
| MPPT Effiffifficiency | 99.90% | |||||||
| Praesidium | ||||||||
| Integrated | PV Input Lightning Protection, Anti-insula Praesidium, PV String Input Reverse Polarity Protection, Nulla Resistor Detection, Residua Current Cras Unit, Output super Current Praesidium, Output Shorted Praesidium, Surge praesidium | |||||||
| Output super intentione Praesidium | DC Type II/AC Type III | |||||||
| Testimonia et signa | ||||||||
| Eget Ordinatio | EN50549, AS4777.2:2015, VDE0126-1-1, IEC61727, VDEN4105-2018, G99 | |||||||
| Salus EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||||
| Generalis Data | ||||
| Temperature dolor operans (℃) | -40~60℃, >45℃ derating; | |||
| Refrigerium | Dolor refrigerationem | |||
| sonitus (dB) | <45 dB | |||
| Communicatio cum BMS | RS485; CAN | |||
| Pondus (kg) | 75 | |||
| Magnitudo (mm) | 527W×894H×294D | |||
| Praesidium Degree | IP65 | |||
| Installation Style | Murus conscendit | |||
| Warranty | V annis | |||
Gratam nostris Ali tabernamhttps://yftechco.en.alibaba.com/productgrouplist-822775923/M6_166mm.html) pro pluribus products et pretium referentia.